Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Biomed Opt ; 27(11)2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36385200

RESUMO

Significance: The internal jugular veins (IJV) are critical cerebral venous drainage pathways that are affected by right heart function. Cardiovascular disease and microgravity can alter central venous pressure (CVP) and venous return, which may contribute to increased intracranial pressure and decreased cardiac output. Assessing jugular venous compliance may provide insight into cerebral drainage and right heart function, but monitoring changes in vessel volume is challenging. Aim: We investigated the feasibility of quantifying jugular venous compliance from jugular venous attenuation (JVA), a noncontact optical measurement of blood volume, along with CVP from antecubital vein cannulation. Approach: CVP was progressively increased through a guided graded Valsalva maneuver, increasing mouth pressure by 2 mmHg every 2 s until a maximum expiratory pressure of 20 mmHg. JVA was extracted from a 1-cm segment between the clavicle and midneck. The contralateral IJV cross-sectional area (CSA) was measured with ultrasound to validate changes in the vessel size. Compliance was calculated using both JVA and CSA between four-beat averages over the duration of the maneuver. Results: JVA and CSA were strongly correlated (median and interquartile range) over the Valsalva maneuver across participants (r = 0.986, [0.983, 0.987]). CVP more than doubled on average between baseline and peak strain (10.7 ± 4.4 vs. 25.8 ± 5.4 cmH2O; p < 0.01). JVA and CSA increased nonlinearly with CVP, and both JVA- and CSA-derived compliance decreased progressively from baseline to peak strain (49% and 56% median reduction, respectively), with no significant difference in compliance reduction between the two measures (Z = - 1.24, p = 0.21). Pressure-volume curves showed a logarithmic relationship in both CSA and JVA. Conclusions: Optical jugular vein assessment may provide new ways to assess jugular distention and cardiac function.


Assuntos
Veias Jugulares , Manobra de Valsalva , Humanos , Veias Jugulares/diagnóstico por imagem , Pressão Venosa Central , Ultrassonografia/métodos
2.
Physiol Rep ; 10(3): e15179, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35150210

RESUMO

Non-contact coded hemodynamic imaging (CHI) is a novel wide-field near-infrared spectroscopy system which monitors blood volume by quantifying attenuation of light passing through the underlying vessels. This study tested the hypothesis that CHI-based jugular venous attenuation (JVA) would be larger in men, and change in JVA would be greater in men compared to women during two fluid shift challenges. The association of JVA with ultrasound-based cross-sectional area (CSA) was also tested. Ten men and 10 women completed three levels of head-down tilt (HDT) and four levels of lower body negative pressure (LBNP). Both JVA and CSA were increased by HDT and reduced by LBNP (all p < 0.001). Main effects of sex indicated that JVA was higher in men than women during both HDT (p = 0.003) and LBNP (p = 0.011). Interaction effects of sex and condition were observed for JVA during HDT (p = 0.005) and LBNP (p < 0.001). We observed moderate repeated-measures correlations (rrm ) between JVA and CSA in women during HDT (rrm  = 0.57, p = 0.011) and in both men (rrm  = 0.74, p < 0.001) and women (rrm  = 0.66, p < 0.001) during LBNP. While median within-person correlation coefficients indicated an even stronger association between JVA and CSA, this association became unreliable for small changes in CSA. As hypothesized, JVA was greater and changed more in men compared to women during both HDT and LBNP. CHI provides a non-contact method of tracking large changes in internal jugular vein blood volume that occur with acute fluid shifts, but data should be interpreted in a sex-dependent manner.


Assuntos
Decúbito Inclinado com Rebaixamento da Cabeça , Veias Jugulares/diagnóstico por imagem , Imagem Óptica/métodos , Sexo , Adulto , Feminino , Humanos , Veias Jugulares/fisiologia , Pressão Negativa da Região Corporal Inferior , Masculino , Imagem Óptica/normas , Sensibilidade e Especificidade
3.
IEEE Trans Biomed Eng ; 68(8): 2582-2591, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33769929

RESUMO

OBJECTIVE: An optical imaging system is proposed for quantitatively assessing jugular venous response to altered central venous pressure. METHODS: The proposed system assesses sub-surface optical absorption changes from jugular venous waveforms with a spatial calibration procedure to normalize incident tissue illumination. Widefield frames of the right lateral neck were captured and calibrated using a novel flexible surface calibration method. A hemodynamic optical model was derived to quantify jugular venous optical attenuation (JVA) signals, and generate a spatial jugular venous pulsatility map. JVA was assessed in three cardiovascular protocols that altered central venous pressure: acute central hypovolemia (lower body negative pressure), venous congestion (head-down tilt), and impaired cardiac filling (Valsalva maneuver). RESULTS: JVA waveforms exhibited biphasic wave properties consistent with jugular venous pulse dynamics when time-aligned with an electrocardiogram. JVA correlated strongly (median, interquartile range) with invasive central venous pressure during graded central hypovolemia (r = 0.85, [0.72, 0.95]), graded venous congestion (r = 0.94, [0.84, 0.99]), and impaired cardiac filling (r = 0.94, [0.85, 0.99]). Reduced JVA during graded acute hypovolemia was strongly correlated with reductions in stroke volume (SV) (r = 0.85, [0.76, 0.92]) from baseline (SV: 79 ± 15 mL, JVA: 0.56 ± 0.10 a.u.) to -40 mmHg suction (SV: 59 ± 18 mL, JVA: 0.47 ± 0.05 a.u.; p 0.01). CONCLUSION: The proposed non-contact optical imaging system demonstrated jugular venous dynamics consistent with invasive central venous monitoring during three protocols that altered central venous pressure. SIGNIFICANCE: This system provides non-invasive monitoring of pressure-induced jugular venous dynamics in clinically relevant conditions where catheterization is traditionally required, enabling monitoring in non-surgical environments.


Assuntos
Veias Jugulares , Pressão Negativa da Região Corporal Inferior , Pressão Venosa Central , Eletrocardiografia , Hemodinâmica , Humanos , Veias Jugulares/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...